Water-cooled high-pressure compressors in the I-series (air & nitrogen) in the pressure range 90 – 420 bar – for heavy-duty operation in industrial applications

BAUER I 52 water-cooled, high-pressure compressor
BAUER I 52 water-cooled, high-pressure compressor
BAUER IB 23 water-cooled, high-pressure compressor
BAUER IB 23 water-cooled, high-pressure compressor
BAUER I 26 water-cooled, high-pressure compressor
BAUER I 26 water-cooled, high-pressure compressor

Cooling of valve heads reduces thermal load: For minimum wear

Installation even under the most difficult ambient conditions: Thanks to dedicated water cooling of the compressor block

Incredibly long-serving and reliable unit: With extended valve service life and low oil consumption

Reduced noise level: Compared with air-cooled units

BAUER I-series water-cooled high-pressure compressors are ideal for installation under the most difficult ambient conditions as well as for use in industrial applications.

By using targeted water cooling between the interstage and afterstage coolers and valve heads, the system enables the majority of the heat produced to be absorbed by the cooling water.

As a result, the multi-stage, industrial high-pressure compressors require very little maintenance and achieve long service lives. At the same time, they are quieter than comparable air-cooled compressors.

All the information you need at your fingertips!

Display B-CONTROL MICRO
Display B-CONTROL MICRO

B-CONTROL MICRO compressor control
The B-CONTROL MICRO is a modern, easy-to-use compressor control with colour display for the control and reliable monitoring of all basic functions. Read more

BK 23 compressor block
BK 23 compressor block

Compressor block
For compressor units with intake pressure, the BK 23 to BK 52 block series feature a pressure-tight crankcase for uniform absorption of the internal gas forces. Read more

Water cooling (heat exchanger)
Water cooling (heat exchanger)

Water cooling
By using targeted water cooling between the interstage and afterstage coolers and valve heads, the system enables the majority of the heat produced to be absorbed by the cooling water. This maintenance-friendly cooling concept is suitable in particular for difficult spatial and ambient conditions where it would not be possible to use an air-cooled compressor.

B-CONTROL III display
B-CONTROL III display

B-CONTROL III
B-CONTROL III is BAUER's premium control system for demanding applications. Read More

Special colours
Special colours

Colour range
Customer-specific paint finishes in other colours or special composition paints (conforming to corrosivity category C5M, for example) are available alongside the standard BAUER paint finishes.

Explosion protection design
Explosion protection design

Explosion protection conforming to ATEX guidelines
Compressor units by BAUER KOMPRESSOREN can be supplied with explosion protection and conforming to ATEX directives.

Start-up configuration
Start-up configuration

Start-up configuration
At and above motor power ratings of 75 kW and in conjunction with the B-CONTROL, a soft starter to protect the unit during starting and effectively reduce starting current is used as standard. The technical alternative is soft staring with a frequency inverter. Read more

Monitoring of intermediate pressures and temperatures
Monitoring of intermediate pressures and temperatures

Monitoring of pressure and temperature
This add-on module for the B-CONTROL control monitors the pressures and temperatures of all compressor stages. Read more

Intake system
Intake system

Intake system
The intake system is needed to supply the compressor with air or gas at a suitable and monitored intake pressure. Read more

Intake buffer vessel
Intake buffer vessel

Intake buffer vessel
To effectively prevent pulsations in the intake area, an intake buffer vessel is installed between the compressor and the upstream gas supply networks and/or control equipment. Read more

SECCANT IV-A
SECCANT IV-A

Treatment systems
BAUER treatment systems for highly compressed air and gases reduce content such as moisture, oil and particles to a permissible level. Read more

B 2000 storage system
B 2000 storage system

Storage systems
Modular high-pressure storage systems by BAUER KOMPRESSOREN are the ideal way to expand a compressor system. Read more

Plate heat exchanger set
Plate heat exchanger set

Plate heat exchanger set
The plate heat exchanger set can be used to build a dedicated enclosed compressor cooling water circuit. In open cooling systems with stream water or sea water or open cooling towers, this is essential in order to operate the compressor with cooling water of suitable quality.

Heat exchanger set
Heat exchanger set

Heat exchanger set
The set consists of an air-to-water heat exchanger which makes it possible to operate water-cooled compressor units independently of a water supply.

Scope of delivery, basic version
Scope of delivery, basic version

Scope of delivery, basic version
Complete compressor unit ready for operation. Read more

I-series, water-cooled compressors, 90 – 365 bar – 50 Hz
Type
designation
Effective
free air delivery ¹
Max. operating
pressure ²
No. of
compr. stages
Speed
approx.
Motor
output
Net weight approx.
  l/min m³/h cfm bar psig   rpm kW kg lbs
IB 23.0-30 1000 60 35.3 365 5300 4 985 30 1000 2200
IB 23.0-37 1500 90 53 365 5300 4 1485 37 1050 2315
I 26.0-55 2400 144 85 365 5300 4 985 55 2690 5930
I 26.0-75 3300 198 117 365 5300 4 1485 75 2950 6500
I 52.0-110 4800 288 170 365 5300 4 985 110 4600 10200
I 52.0-160 6600 396 233 365 5300 4 1485 160 4900 10800
I-series, water-cooled compressors, 90 – 365 bar – 60 Hz
Type
designation
Effective
free air delivery ¹
Max. operating
pressure ²
No. of
compr. stages
Speed
approx.
Motor
output
Net weight approx.
  l/min m³/h cfm bar psig   rpm kW kg lbs
IB 23.0-30 1150 69 40.6 365 5300 4 1170 30 1000 2200
IB 23.0-45 1750 105 61.8 365 5300 4 1770 45 1090 2400
I-series, water-cooled compressors, 90 – 420 bar – 50 Hz
Type
designation
Effective
free air delivery ¹
Max. operating
pressure ²
No. of
compr. stages
Speed
approx.
Motor
output
Net weight approx.
  l/min m³/h cfm bar psig   rpm kW kg lbs
I 26.0-90-420 3300 198 116 420 6100 4 1485 75 3080 6790
I 52.0-160-420 6600 396 233 420 6100 4 1485 160 4000 8800

1 Free air delivery according to ISO 1217, power consumption at maximum final pressure under certain conditions. Other ambient conditions result in different performance data.
2 Max. operating pressure = max. safety valve pressure setting; reduced switch-off pressure.