SECCANT regeneration dryer: Treating air and gas reliably and with zero maintenance – for high operating hour counts, high free air delivery rates and increased ambient temperatures

BAUER SECCANT III high-pressure regeneration dryer for air and gas treatment
BAUER SECCANT III high-pressure regeneration dryer for air and gas treatment
BAUER SECCANT IV high-pressure regeneration dryer for air and gas treatment
BAUER SECCANT IV high-pressure regeneration dryer for air and gas treatment
BAUER SECCANT 550/420
BAUER SECCANT 550/420

Dedicated control: Independent of the compressor

Continuous drying: With two dryer chamber dryer modes working in parallel (dryer mode and regeneration mode)

Optimum FAD for your application: For air, gases and high operating hour counts

The regeneration dryers in the SECCANT series from BAUER KOMPRESSOREN for the pressure range from 50 – 420 bar have been designed for the treatment of air and gases in applications in which operating hour counts, free air delivery rates and ambient temperatures are high.

As units delivered ready for operation, the high-pressure dryers are equipped with electronic control, smooth switch-over between regeneration and work cycles as standard, as well as featuring upstream separation and a particle filter.

The impressive unit concept also makes for easy integration into the overall system.

Activated carbon filters for oil removal and CO conversion (for the treatment of breathing air and air for use in medical applications, for example) can be added to meet your specific individual industrial requirements and production needs.

All the information you need at your fingertips!

B-CONTROL control
B-CONTROL control

Control
The use of a dedicated control system as standard makes the SECCANT series independent of the compressor control system. All that is required is a start/stop signal from the compressor control.
The B-CONTROL dryer control used also supports the transfer of additional data to the compressor control or other monitoring equipment via bus cable.

Continuous drying
Continuous drying

Continuous drying
The two dryer chambers work in parallel: one dryer chamber is operated in drying mode, the second is operated in regeneration mode. Automatic switch-over between the modes is controlled via the control. This ensures a constant supply of treated medium.

Pressure retention check valve
Pressure retention check valve

Pressure retention valve
Equipping the SECCANT regeneration dryer with a compatible pressure retention valve safeguards the minimum pressure in the filter housings. Setting a minimum pressure prevents the maximum flow speed in the filter housing being exceeded. Contact time between medium and processing­equipment is thus assured right from the outset.

B-SECURUS filter monitoring system
B-SECURUS filter monitoring system

B-SECURUS filter monitoring system
The B-SECURUS filter monitoring system monitors the saturation of the filter cartridge with moisture. The cartridge performs best at a pressure dew-point of -20°C. Information is displayed via the B-CONTROL control display. Read more

A version with activated carbon
A version with activated carbon

A version (activated carbon)
The regeneration dryers in the SECCANT series can be fitted with an additional filter housing as an optional extra. The filter contains activated carbon which removes oil and hydrocarbons from the compressed medium.

Dew-point monitoring
Dew-point monitoring

Dew-point monitoring
Dew-point monitoring is integrated into the regeneration dryer and linked to the control. This enables the moisture content of the compressed air to be monitored and displayed at all times. Values can be set at which warnings and alarms should be output and the compressor unit switched off automatically.

Gas-tight design (compression fitting)
Gas-tight design (compression fitting)

Gas-tight design
All BAUER KOMPRESSOREN treatment systems are also available in gas-tight design.
This means that they support the no-loss treatment of expensive gases.

CO conversion
CO conversion

CO conversion
During the air treatment process, the poisonous carbon monoxide (CO) found in the air is converted into carbon dioxide (CO2). As the proportion of CO is low, the CO2 concentration only increases slightly.
Depending on the air treatment system, CO conversion will take place either in a filter housing together with oil removal or in a separate filter housing.
The "CO conversion" equipment option is only possible in conjunction with the "Oil removal" option.

Scope of delivery, basic version
Scope of delivery, basic version

Scope of delivery, basic version
SECCANT regeneration dryer. Read more

BAUER regeneration dryer SECCANT
BAUER SECCANT high-pressure regeneration dryer – for air, nitrogen, helium and argon – pressure dew point -20°C
Type designation Free air capacity Pressure range
  l/min m³/h cfm bar
SECCANT III 500 – 1500 30 – 90 18 – 53 90 – 350 / 420
SECCANT IV 1500 – 3500 90 – 210 53 – 124 90 – 350 / 400
BAUER SECCANT regeneration dryer – for air and nitrogen – pressure dew point -20°C, -40°C or -55°C
Type designation Free air capacity Pressure range
  l/min m³/h cfm bar
SECCANT x/50 1000 – 12000 60 – 720 35 – 424 25 – 50
SECCANT x/100 1000 – 15000 60 – 900 35 – 530 50 – 100
SECCANT x/250 1000 – 25500 60 – 1530 35 – 900 110 – 250
SECCANT x/420 1800 – 30000 108 – 1800 64 – 1059 250 – 420